Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
28
4.15 Acron Super Fast Protocol (9)
9RRLLLssssAAAACCCCCCCC[DC4]
Where, 9 : Protocol number
RR : Virtual Receiver number
LLL : Virtual Line number
ssss : Spaces
AAAA : Account code
CCCC : Channel 1-4
CCCC : Channel 5-8
[DC4] : Terminator, 14 Hex.
4.16 Silent Knight FSK1 (E)
ERRLLLssssssAAAAXXssss[DC4]
Where:
E : FSK1 protocol identifier.
RR : Virtual receiver number.
LLL : Virtual Line number.
s : spaces.
AAAA : the account number.
XX : alarm code.
s : spaces.
Possible alarm codes (XX) are as follows:
00 Alarm Panic
01-08 Alarm 01-08 41-49 Closing 1-9
09 Hold-up 50-59 Bypass 10-19
10-19 Alarm 10-19 60 Trouble AC
20-29 Alarm Restore 10-19 61-68 Trouble 1-8
30 Test Code 69 Trouble Bat
31 Trouble Line 1 70 Restore AC
32 Trouble Line 2 71-78 Restore 1-8
33 Expand Trouble 79 Restore Bat
34 Forced Access 80 Access
35 Restore Line 1 81-89 Access 1-9
36 Restore Line 2 90 Opening
37 Expand Restore 91-99 Opening 1-9
38 Cancel Code
39 Data Lost
40 Closing
Comentarios a estos manuales