
Form Number.: 7-3005 File Name: SG Automation Output Revision/Date: 01/May 3, 2005
Department: Engineering
Division: Embedded Software Form Template Owner: Jeff Cougler
53
6.0 Detailed Description of Com Outputs
6.1 SG outputs (TCP/IP and RS232)
6.1.1 RS-232 Configuration
The serial ports are RS-232 communications ports that are used to send alarm events to a computer running automation
software. The user can configure the port settings
.
Baud Rate: 1200, 2400, 4800, 9600, 19200 and 38400.
Data Bits: 7, 8 or 9
Parity: No Parity, Odd Parity or Even Parity.
Stop Bits: 2
NOTE: If 7 data bits are configured, the data will be limited to ASCII.
6.2 TCP/IP Sockets and Ports
TCP/IP ports are available only on the System II, System III and MLR2000 receivers. Each CPM has a user selectable IP
address (which is applied on the next reboot) and Port base address. By default the CPM2000 will use IP address 10.0.7.100
on the primary and 10.0.7.101 on the secondary. The default the CPM3 is also 10.0.7.100.
Base Port # Port Name
1025 SG-Automation Port
1026 UCS-Automation Port (MLR2000 only)
Comentarios a estos manuales